Median measured P ÷ modelled Pmp per irradiance bin. Hover a cell for V ÷ Vmp and
I ÷ Imp: low V with normal I points at a local-peak lock or mismatch; normal-to-high V with
low I at a current limit. The hover also gives I ÷ the model curve at the measured voltage:
about 1.00 means the operating point sits on the curve (any loss is where the tracker holds it);
below 1 means less current than the array should give at that voltage (effective irradiance, soiling,
mismatch or measurement).
Module temperature QC
Each 15-min reading from ModuleTemperature1/2/3 is dropped if missing, exactly 0 °C, out of range,
logged in the sensor-issue log, stuck for the day, colder than ambient − 3 °C in sun, or more than
8 °C from the other valid sensors. The rest are averaged; with none left, T is estimated from ambient
(NOCT model).